Arshad Amari, Hudabiyah and Abdul Rahim, Ruzairi and Fazalul Rahiman, Mohd. Hafiz and Pusppanathan, Jaysuman (2011) Front-end design of an ultrasonic tomography measurement system. Jurnal Teknologi, 54 (1). pp. 289-298. ISSN 0127–9696 (Print); 2180-3722 (Online)
|
PDF (Full Text)
349kB |
Official URL: http://dx.doi.org/10.11113/jt.v54.815
Abstract
This paper explains the front–end system design of an ultrasonic tomography. In this paper, the ultrasonic tomography techniques implements a non–invasive techniques which using 16 transceivers to investigate the multiphase flow of the pipelines. The flows include solid, gas and liquid phase in 100 mm pipelines. The advantages of using transceiver rather than separate transmitter receiver are discussed in this paper. The sensor arrangement, measurement techniques and hardware preparation are also discussed in this paper. The circuit design details, including the transmitter, receiver and peak detector are also presented and explained. This paper will be useful for the use of further ultrasonic tomography system development.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | ultrasonic tomography, multiphase flow, non–invasive ultrasonic, transceivers, peak detector |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) |
Divisions: | Electrical Engineering |
ID Code: | 44936 |
Deposited By: | Haliza Zainal |
Deposited On: | 21 Apr 2015 03:31 |
Last Modified: | 01 Nov 2017 04:17 |
Repository Staff Only: item control page