Mohd. Suri, Mohd. Syafiq and Safura Hashim, Nor Liyana and Syahrom, Ardiyansyah and Abd. Latif, Mohd. Juzaila and Harun, Muhamad Noor (2020) Influence of dimple depth on lubricant thickness in elastohydrodynamic lubrication for metallic hip implants using fluid structure interaction (FSI) approach. Malaysian Journal of Medicine and Health Sciences, 16 . pp. 28-34. ISSN 1675-8544
Full text not available from this repository.
Abstract
Introduction: The lubricant thickness in clearance between bearing surfaces for metallic hip implants are currently incapable of accommodating the motion experienced (high load and low entraining motion) in hip walking cycle. Thus, micro-dimpled surfaces were introduced onto surfaces of metallic acetabular cups to improve lubricant thickness. Micro-dimpled surface is a method of advanced surface improvement to increase the lubricant thickness in various tribological applications, such as hip implants. However, the application of micro-dimpled surfaces in hip implants has not yet been explored adequately. Therefore, this study aims to identify the influence of micro-dimpled depth on lubricant thickness elastohydrodynamically for metallic hip implants using Fluid-Structure Interaction (FSI) approach. Methods: Fluid-Structure Interaction (FSI) approach is an alternative method for analysing characteristics of lubrication in hip implant. Dimples of radius 0.25 mm and various depths of 5ìm, 45ìm and 100ìm were applied on the cup surfaces. The vertical load in z-direction and rotation velocity around y-axes representing the average load and flexion-extension (FE) velocity of hip joint in normal walking were applied on Elastohydrodynamic lubrication (EHL) model. Results: The metallic hip implants with micro-dimpled surfaces provided enhanced lubricant thickness, namely by 6%, compared to non-dimpled surfaces. Furthermore, it was suggested that the shallow depth of micro-dimpled surfaces contributed to the enhancement of lubricant thickness. Conclusion: Micro-dimpled surfaces application was effective to improve tribological performances, especially in increasing lubricant thickness for metallic hip implants.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | lubricant thickness, metallic hip implants, micro-dimpled surfaces |
Subjects: | Q Science > Q Science (General) T Technology > TA Engineering (General). Civil engineering (General) |
Divisions: | Biosciences and Medical Engineering |
ID Code: | 90553 |
Deposited By: | Yanti Mohd Shah |
Deposited On: | 30 Apr 2021 14:55 |
Last Modified: | 30 Apr 2021 14:55 |
Repository Staff Only: item control page