Universiti Teknologi Malaysia Institutional Repository

Air permeability of hardener-free epoxy-modified mortars using NDT

Bhutta, Muhammad Aamer Rafique (2011) Air permeability of hardener-free epoxy-modified mortars using NDT. Concrete Research Letters, 2 (2). pp. 241-248. ISSN 2180-1371

[img] HTML
92kB

Abstract

The purpose of this study is to investigate the air permeability of hardener-free epoxymodified mortars by applying a non-destructive testing method developed by RILEM Technical Committee 189-NEC. Considering intelligent patch materials for the repair work of deteriorated reinforced concrete structures, hardener-free epoxy-modified mortars using a bisphenol A-type epoxy resin without any hardener are prepared with various polymercement ratios, and tested for moisture content, air permeability and strength. As a result, although there is no significant strength improvement, the coefficient of air permeability of the hardener-free epoxy-modified mortars is markedly decreased with an increase in the polymer-cement ratio.

Item Type:Article
Uncontrolled Keywords:epoxy-modified mortar, air permeability, hardener-free epoxy resin, polymercement ratio, strength
Subjects:T Technology > TA Engineering (General). Civil engineering (General)
Divisions:Civil Engineering
ID Code:34390
Deposited By: Liza Porijo
Deposited On:17 Feb 2014 01:33
Last Modified:15 Feb 2017 00:26

Repository Staff Only: item control page