Universiti Teknologi Malaysia Institutional Repository

Determination of Vanadium(IV) and Vanadium(V) in benfield samples by IEC with conductivity detection

Tengku Azmi, Tengku Sharifah Marliza and Mohd. Yusoff, Abdull Rahim and Abdul Karim, K. J. (2010) Determination of Vanadium(IV) and Vanadium(V) in benfield samples by IEC with conductivity detection. Chromatographia, 72 (1). 141 - 144. ISSN 0009-5893 (Print) , 1612-1112 (Online)

Full text not available from this repository.

Official URL: http://dx.doi.org/10.1365/s10337-010-1630-x

Abstract

In this study, the determination of vanadium valence state, V(IV) and V(V) has been achieved using ion-exchange chromatography with conductivity detector. In this method, V(IV) was determined as V(IV)-EDTA complex and V(V) as vanadate ion. Determination of V(IV) was successfully done using 3 mM carbonate/bicarbonate/EDTA at pH 8.6 as the eluent. The additive, EDTA in the mobile phase did not seem to interfere with the V(IV) analysis. The detection of V(V) was achieved with 5 mM disodium hydrogen phosphate buffer at pH 10.4. A linear calibration graph over VO3− and V(IV) with concentration ranges 5–15 mg L−1 gave the detection limit at 0.09 and 0.1 mg L−1, respectively. Both V(IV) and V(V) were successfully determined in Benfield sample, with concentrations of V(IV) and V(V) at 4 and 11,000 mg L−1, respectively.

Item Type:Article
Uncontrolled Keywords:conductivity detection, benfield sample, vanadium
Subjects:T Technology > TA Engineering (General). Civil engineering (General)
Divisions:Civil Engineering
ID Code:25097
Deposited By: Narimah Nawil
Deposited On:16 May 2017 10:28
Last Modified:21 Mar 2018 00:38

Repository Staff Only: item control page