Abd. Rahman, Ahmad Baharuddin and Shaedon, Suhaimi and Lim, Chin Yee (2009) Behaviour of bolted beam-to-column precast concrete connections under gravity and lateral loads. In: 7th Asia Pacific Structural Engineering and Construction Conference 2009 (APSEC 2009) & 2nd European Asian Civil Engineering Forum (EACEF 2009), 2009, Awana Porto Malai, Langkawi.
Full text not available from this repository.
Official URL: http://dms.library.utm.my:8080/vital/access/manage...
Abstract
This paper reports the study on the behaviour of a newly developed precast concrete beam-to-column connection. In this study, a total of two specimens were tested to investigate the behavior of the proposed precast concrete beam-to-column connections, which involves dry bolted cast in-situ connection. The behavior of the connections was studied through load-deflection, moment-rotation, and load-strain relationships. The results obtained from both cases have been compared to the results obtained from monolithic specimen. The results indicated that the bolted connection performed better than the monolithic specimen due to the good connection between beam and column.
Item Type: | Conference or Workshop Item (Paper) |
---|---|
Uncontrolled Keywords: | in-situ connection, load-strain relationships |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) |
Divisions: | Civil Engineering |
ID Code: | 14858 |
Deposited By: | Narimah Nawil |
Deposited On: | 15 Sep 2011 02:36 |
Last Modified: | 30 Jun 2020 08:39 |