Universiti Teknologi Malaysia Institutional Repository

A comparison between blast debris from lightweight and normal concrete structure

Othman, Ahmad Mazlan (2008) A comparison between blast debris from lightweight and normal concrete structure. Masters thesis, Universiti Teknologi Malaysia, Faculty of Civil Engineering.

[img]
Preview
PDF
139kB

Abstract

This is a research on Blast Debris Field Study - Comparison of Blast Debris from Lightweight and Normal Concrete with the focus on throw distance, shape and size of concrete fragments. This report presents the review on available literature references on the subject that contribute to the understanding on the selected material, blast loading and blast debris. The testing requirements and method adopted are outlaid with the debris collection technique and data sheets. Selection of the scaled test model, design and specifications, construction material and computations of suitable blast loading for the test are presented. Scaled models from lightweight and normal concrete are casted and blasted using adequate explosive charge. A full report on the execution of the blast test and analysis of the result are presented. Blast debris analysis was conducted and the result proved that debris from lighter density concrete produce shorter throw distance. Density of concrete does not influence the shape and size of debris. Lightweight concrete possess the properties that can reduce the safety distance and reduce risk to human and property.

Item Type:Thesis (Masters)
Additional Information:Thesis (Sarjana Kejuruteraan (Awam Struktur)) - Universiti Teknologi Malaysia, 2008; Supervisor : Dr. Salihuddin Radin Sumadi
Uncontrolled Keywords:Blast Debris Field Study, concrete structure, size of debris
Subjects:T Technology > TA Engineering (General). Civil engineering (General)
Divisions:Civil Engineering
ID Code:9655
Deposited By: Narimah Nawil
Deposited On:18 Jan 2010 07:55
Last Modified:29 Jun 2018 21:51

Repository Staff Only: item control page