Universiti Teknologi Malaysia Institutional Repository

Development of underwater radiography scanner for reactor-pool experiment at the TRIGA PUSPATI reactor

Husain, M. A. A. and Hashim, S. and Zakaria, N. and Mohamed Zin, M. R. (2018) Development of underwater radiography scanner for reactor-pool experiment at the TRIGA PUSPATI reactor. MethodsX, 5 . pp. 1346-1363. ISSN 2215-0161

[img]
Preview
PDF
550kB

Official URL: http://dx.doi.org/10.1016/j.mex.2018.10.011

Abstract

This paper describes the development of a custom-designed underwater scanner to support the experimental works for characterizing irradiated fuel stored in the TRIGA PUSPATI pool by means of radiography technique. Materials used to build the scanner are aluminum 6061, lead and teflon. Three main units that make up the scanner are rig structure, arm block and collimator. Collimator is designed to control radiation exposure by opening and closing the shutter. The experimental works were conducted underwater at 5-m depth hence water tightness is one of the main design criteria. Radiation in terms of gamma energy is captured by radiography film which after development and processing revealed the image of the radiation impact in terms of pixel and gray value. The film size used is 4in x 8in which was slot in the collimator. To validate the scanner, fuel element containing 8.5 wt% and 12 wt% enriched Uranium 235 were used. It was found that the experimental output is consistent with the fuel type and confirmed that the scanner is viable for fuel characterization study.

Item Type:Article
Uncontrolled Keywords:Collimator, Pixel, Radiography, RTP, Scanner, Underwater scanner using radiography technique
Subjects:Q Science > QC Physics
Divisions:Science
ID Code:79907
Deposited By: Narimah Nawil
Deposited On:28 Jan 2019 06:59
Last Modified:27 Jul 2020 03:43

Repository Staff Only: item control page