Possibilities of using void to improve natural cross ventilation in high-rise low-cost residential building

Sapian, Abdul Razak (2004) Possibilities of using void to improve natural cross ventilation in high-rise low-cost residential building. PhD thesis, Universiti Teknologi Malaysia, Faculty of Built Environment.

[img] PDF
Restricted to Repository staff only

40Mb
[img] PDF (Abstract)
147Kb
[img] PDF (Table of Contents)
653Kb
[img] PDF (1st Chapter)
552Kb

Abstract

This thesis focuses on the study to investiyate the possibilities of improving natural cross ventilation (in term of intemal air velocity, mls) in high-rise low-cost residential building (HRLCRB) in Kuala Lumpur. The HRLCRB design is found complied with the minimum requirement of natural ventilation in the Uniform Building Bye-Law (UBBL) and has architectural design that could permit optimum natural ventilation. However the natural ventilation and thermal comfort performance is still not achieved with respect to its internal air velocity performance. Cross ventilation has been suggested by many researchers as one of the most effective techniques of natural ventilation for thermal comfort. However, it is also one of the least understood parts in controlling indoor climate through passive design approach. In this thesis the proposed design solution is by introducing a void at specific floor level or height ratio of the HRLCRB. The research involves three stages. First, the inventory exercises. This is to determine the most basic and typical typology of HRLCRB built by Dewan Bandaraya Kuala Lumpur (DBKL). Second, computer simulation using Computational Fluid Dynamic (CFD) technique with specific software called FloVent. This software is used to estimate the vertical pressure distribution and to investigate the potential of the proposed design solution. Finally, empirical method is used to predict the intemal air velocity. The result of the simplified building configuration is used as a basis of comparison. The result shows that the void affects the vertical pressure distribution. However, the effect is insignificant to improve the internal air velocity performance at the HRLCRB.

Item Type:Thesis (PhD)
Additional Information:Thesis (Ph.D.) - Universiti Teknologi Malaysia, 2004; Supervisor I : Assoc. Prof. Dr. Nor Haliza Madros; Supervisor II : Assoc. Prof. Dr. Mohd. Hamdan Ahmad
Uncontrolled Keywords:natural cross ventilation, void, uniform building bye-law(UBBL), case study, high-rise low-cost residential building (HRLCRB)
Subjects:T Technology > TH Building construction
Divisions:Built Environment
ID Code:5984
Deposited By: Ms Zalinda Shuratman
Deposited On:24 Jul 2008 03:48
Last Modified:29 Aug 2012 05:32