Universiti Teknologi Malaysia Institutional Repository

Eccentrically loaded externally confined HSC columns

Ma, Chow Khun and Awang, Abdullah Zawawi and Omar, Wahid (2013) Eccentrically loaded externally confined HSC columns. In: GEOCON 2013, 2013.

Full text not available from this repository.

Official URL: https://www.researchgate.net/publication/259497224...

Abstract

The application of steel-straps confinement has been proven to be effective in increasing the strength and ductility of High-Strength Concrete (HSC) column comparable to Fiber-Reinforced Polymer. However, most of the research of confined HSC column has mainly concentrated on concentric loading. In actual practical condition, most of the columns are subjected to eccentric loading. The scarcity of the experimental data for eccentric loaded confined HSC column has prevented the potential use of this type of structure element. In this paper, five short HSC columns were tested. The specimens were confined with steel-straps and tested with 25mm and 50 mm eccentric loading. The results show that steel-straps confinement increases the strength and deformability of high-strength concrete column, although the confinement effects in eccentrically loaded columns are not as pronounces as concentrically loaded column.

Item Type:Conference or Workshop Item (Paper)
Uncontrolled Keywords:external confinement, high-strength concrete, steel-straps, eccentricity
Subjects:T Technology > TA Engineering (General). Civil engineering (General)
Divisions:Civil Engineering
ID Code:39191
Deposited By: Liza Porijo
Deposited On:30 Jun 2014 08:14
Last Modified:28 Sep 2017 03:36

Repository Staff Only: item control page