Chia, Kau Pui and Li, Ooi Ke and Yuong, Teh Shyong and Singh, Om Prakash and Mohd. Faudzi, Ahmad Athif and Sornambikai, Sundaram and Madhanagopal, Jagannathan (2021) New real-time force monitoring device with enhanced accuracy for evaluation of applied force during the joint mobilization technique. Technology and Health Care, 29 (4). pp. 829-836. ISSN 0928-7329
Full text not available from this repository.
Official URL: http://dx.doi.org/10.3233/THC-202414
Abstract
BACKGROUND: Force Monitoring Devices (FMDs) reported in the literature to monitor applied force during Joint Mobilization Technique (JMT) possess complex design/bulky which alters the execution of treatment, has poor accuracy and is unable to feel the resistance provided by soft tissues limits its usage in the clinical settings. OBJECTIVES: This study aims to develop a highly accurate, portable FMD and to demonstrate real-time monitoring of force applied by health professionals during JMT without altering its execution. METHODS: The FMD was constructed using the FlexiForce sensor, potential divider, ATmega 328 microcontroller, custom-written software, and liquid crystal display. The calibration, accuracy, and cyclic repeatability of the FMD were tested from 0 to 90 N applied load with a gold standard universal testing machine. For practical demonstration, the FMD was tested for monitoring applied force by a physiotherapist while performing Maitland's grade I to IV over the 6th cervical vertebra among 30 healthy subjects. RESULTS: The obtained Bland-Altman plot limits agreement for accuracy, and cyclic repeatability was -1.57 N to 1.22 N, and -1.26 N to 1.26 N, respectively with standard deviation and standard error of the mean values of 3.77% and 0.73% and 2.15% and 0.23%, respectively. The test-retest reliability of the FMD tested by the same researcher at an interval of one week showed an excellent intra-class correlation coefficient of r= 1.00. The obtained force readings for grade I to IV among 30 subjects ranged from 10.33 N to 45.24 N. CONCLUSIONS: Appreciable performance of the developed FMD suggested that it may be useful to monitor force applied by clinicians during JMT among neck pain subjects and is a useful educational tool for academicians to teach mobilization skills.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | force monitoring device, joint mobilization, neck pain, reliability |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Electrical Engineering |
ID Code: | 94771 |
Deposited By: | Yanti Mohd Shah |
Deposited On: | 29 Apr 2022 22:26 |
Last Modified: | 29 Apr 2022 22:26 |
Repository Staff Only: item control page