Lai, Yee Qing and Wan Alwi, Sharifah Rafidah and Abdul Manan, Zainuddin (2019) Customised retrofit of heat exchanger network combining area distribution and targeted investment. Energy, 179 . pp. 1054-1066. ISSN 0360-5442
Full text not available from this repository.
Official URL: http://dx.doi.org/10.1016/j.energy.2019.05.047
Abstract
Heat exchanger network (HEN) retrofit plays a major role in solving environmental issues and improving plants’ performance. Development of HEN retrofit graphical tools has recently focused on detailed representation of existing HEN to facilitate retrofit problem-solving. This work presents a new customised approach for HEN retrofit that uses a combination of individual stream temperature versus enthalpy plot (STEP) to map hot and cold streams, a heat exchanger area versus enthalpy (A vs H) plot to minimise the required overall heat exchanger area and graphical cost screening tool and strategies to steer and customise a retrofit design toward a desired investment payback period. Application of the new retrofit methodology on a sunflower oil production plant shows comparable energy savings and 20% shorter payback period as compared other established retrofit methodologies.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | pinch analysis, area distribution, targeted investment |
Subjects: | Q Science > QD Chemistry T Technology > TP Chemical technology |
Divisions: | Chemical and Energy Engineering |
ID Code: | 89120 |
Deposited By: | Yanti Mohd Shah |
Deposited On: | 26 Jan 2021 08:44 |
Last Modified: | 26 Jan 2021 08:44 |
Repository Staff Only: item control page