Wan Ali, Wan Nor Azita and Azman, Anis Fitri Afira and Samsudin, Mohd. Dinie Muhaimin and Mohd. Zaini Makhtar, Muaz and Ibrahim, Norazana and Md. Kasmani, Rafiziana (2018) Optimisation of wastewater volume of single chamber biological cathodic protection system. Chemical Engineering Transactions, 63 . pp. 415-420. ISSN 2283-9216
Full text not available from this repository.
Official URL: https://doi.org/0.3303/CET1863070
Abstract
In this study, the concept of Microbial Fuel Cells (MFCs) was applied in the biological cathodic protection (CP) system in order to protect steel pipe. There are various factors affect the performance of the system including the volume of the medium.The purposes of this study were to analyse and optimise the effect of volume ratio of wastewater to the sand on biological CP performance by using Taguchi method. The maximum performance of biological CP in this study was obtained at the largest volume ratio. The orthogonal array and the signal-to-noise ratio (S/N) were employed to study the effect of volume ratio on performance of biological CP. The CP potential vs. copper sulfate electrode (CSE) was -835 mV. It shows that the corrosion of carbon steel pipe was reduced since the native potential of the carbon steel pipe vs. CSE was -531 mV.
Item Type: | Article |
---|---|
Subjects: | T Technology > TP Chemical technology |
Divisions: | Chemical and Energy Engineering |
ID Code: | 84379 |
Deposited By: | Siti Nor Hashidah Zakaria |
Deposited On: | 28 Dec 2019 01:55 |
Last Modified: | 28 Dec 2019 01:55 |
Repository Staff Only: item control page