Universiti Teknologi Malaysia Institutional Repository

An improved readout topology of resistive sensor array for reduced measurement error

Talib, D. N. N. and Shafie, S. and Hamidon, M. N. and Ahmad, F. (2016) An improved readout topology of resistive sensor array for reduced measurement error. In: IEEE International Circuits and Systems Symposium, ICSyS 2015, 2 - 4 Sept 2015, Langkawi, Malaysia.

Full text not available from this repository.

Official URL: https://www.scopus.com/inward/record.uri?eid=2-s2....

Abstract

Readout circuit integrated with large scale sensors array is important for improving the effectiveness of data acquisition system. However to design such system, it will require a variety of additional components which contributes to the increment of power consumption. In this paper we proposed an improved method of readout topology for resistive sensor array to reduce the measurement error. A new equation is also proposed to obtain the resistance value. A simulation has been done on 8x8 matrix sensor array represented by 64 fixed resistors and 8 standard reference resistors. The results show that the optimum reference resistance is 510 Ω for the value range between 100 Ω and 100 kΩ, and the improved percentage error is kept to be lower than 5%.

Item Type:Conference or Workshop Item (Paper)
Uncontrolled Keywords:readout circuit, readout topology, Resistive sensor, sensor array
Subjects:T Technology > T Technology (General)
Divisions:Malaysia-Japan International Institute of Technology
ID Code:73450
Deposited By: Mohd Zulaihi Zainudin
Deposited On:20 Nov 2017 08:42
Last Modified:20 Nov 2017 08:42

Repository Staff Only: item control page