Universiti Teknologi Malaysia Institutional Repository

Thermodynamic analysis of ejector as an expansion device on split-type air conditioner using R410A as working fluid

Sumeru, Kasni and Nasution, Henry and Ani, Farid Nasir (2013) Thermodynamic analysis of ejector as an expansion device on split-type air conditioner using R410A as working fluid. In: International Conference on Mechanical Engineering, ICOME 2013, 19-21 Sep,2013, Mataram, Lombok, Indonesia.

Full text not available from this repository.

Official URL: http://dx.doi.org/10.4028/www.scientific.net/AMM.4...

Abstract

Typically the split-type air conditioner uses a capillary tube as expansion device. To enhance the performance of the system, an ejector can be applied as expansion device to replace capillary tube. Based on the numerical modeling, the coefficient of performance (COP) of standard cycle using R410A as working fluid was slightly lower than that of R22. The use of an ejector as an expansion device on a split-type air conditioner using R410 increased the COP by 10.8%. Also, R410A has a lower total GWP impact compared with R22, which reduce negative impact on the environment.

Item Type:Conference or Workshop Item (Paper)
Uncontrolled Keywords:ejector, expansion device
Subjects:T Technology > TJ Mechanical engineering and machinery
Divisions:Mechanical Engineering
ID Code:63632
Deposited By: Siti Nor Hashidah Zakaria
Deposited On:15 Jun 2017 02:33
Last Modified:15 Jun 2017 02:33

Repository Staff Only: item control page