Universiti Teknologi Malaysia Institutional Repository

Targeting method of heat exchanger network in olefin unit of oil refinery

Mohammad, Roslina and Othman, Norazli and Sharifi, Davoud and Sharifi, Foad and A. Kadir, Zuritah (2015) Targeting method of heat exchanger network in olefin unit of oil refinery. In: Proceedings of the 4th World Virtual Conference on Applied Sciences & Engineering Applications, 28-30 Nov 2015, Kuala Lumpur, Malaysia.

Full text not available from this repository.

Official URL: http://www.akademiabaru.com/wvcasea2015/

Abstract

Optimum design of HEN can cause significant reduction in the total cost of the plant. Targeting method using pinch analysis diagrams was presented to find out investment cost required and the period of return of the investment of optimization of the refinery system. This method can be done by knowing the amount of ΔTmin and by pointing the composite curve of saving vs investment (S-I curve).The targeting method is the modification of the system that need to be done to avoid movement of heat exchangers in order to minimize the return of the investment. This method can assist refineries management to make decision in order to optimize the refinery system.Result shows that refinery can reduce the temperature on the main tower until 9.65MW and the investment will be $360,000 with the time of the return cost being 7.7 months.

Item Type:Conference or Workshop Item (Paper)
Uncontrolled Keywords:targeting, pinch cross diagram
Subjects:T Technology > TJ Mechanical engineering and machinery
Divisions:Mechanical Engineering
ID Code:60441
Deposited By: Haliza Zainal
Deposited On:24 Jan 2017 02:54
Last Modified:11 Apr 2022 00:49

Repository Staff Only: item control page