Chee, Pei Song and Abdul Rahim, Ruzairi and Arsat, Rashidah and Hashim, Uda and Leow, Pei Ling (2013) Bidirectional flow micropump based on dynamic rectification. Sensors and Actuators, A: Physical, 204 . pp. 107-113. ISSN 0924-4247
Full text not available from this repository.
Official URL: http://dx.doi.org/10.1016/j.sna.2013.09.033
Abstract
This paper proposes a new bidirectional pumping principle based on a dynamic rectification mechanism. The pump is composed of a moveable actuation platform and a gourd-shaped chamber, whose role is to behave as both a rectification and a pumping structure. An asymmetrically deflected membrane induces a differential pressure across the chamber and thus generates a pumping effect. The stream flow field inside the chamber was verified by numerical simulations. Furthermore, the feasibility of the pump was examined by developing a poly-dimethylsiloxane (PDMS)-based prototype using micro-electromechanical (MEMS) fabrication technology. Because the pumping performance is directional, the micropump characteristics were evaluated at different actuation points along the membrane. In addition, the operating performance was assessed over a range of low driving frequencies (1-10 Hz, in 1 Hz increments) and over a nominal frequency ranges (5-55 Hz, in 5 Hz increments). The proposed micropump exhibits maximum flow rates of 1.52 ml/min in the forward direction and 1.48 ml/min in the reverse direction, with resonance frequencies of 15 Hz and 20 Hz, respectively. The presented pump offers advantage in future disposable microfluidics applications due to its bi-directional properties, low fabrication cost and modular architecture.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | bi-directional micropumps, dynamic structure valve, electromagnetic actuation, numerical simulation |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Electrical Engineering |
ID Code: | 50300 |
Deposited By: | Siti Nor Hashidah Zakaria |
Deposited On: | 02 Dec 2015 02:10 |
Last Modified: | 30 Nov 2018 06:55 |
Repository Staff Only: item control page