Mohd. Yusof, Mohd. Rashid and H., Norelyza (2013) Performance of MR-Deduster: a case study of a palm oil mill plant. Advanced Materials Research, 664 (n/a). pp. 133-137. ISSN 1662-8985
Full text not available from this repository.
Abstract
Multi-cyclones is commonly usedin the palm oil mill industry as particulate pollution arrestor. However, its ability in capturing particulate matter (PM) especially the fine particulate size fraction is limited. Thus, study has been carried out to investigate and predict the performance of MR-deDuster, a multi-cyclones unit developed as particulate emission control device in palm oil mill plant. The MR-deDuster is intentionally developed to overcome particulate emission issue facing by industries that generate particulate especially the palm oil mill industry. A number of semi-empirical theories were used to predict the performance of MR-deDuster. Based on the prediction, the MR-deDuster manages to capture particulate size 3.8µm at 50% particulate collection efficiency. The MR-deDuster also manages to achieve more than 90% for total particulate collection efficiency with low pressure drop.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Air pollution, multi-cyclones, particulate emission, palm oil mill fly ash |
Subjects: | Q Science |
Divisions: | Malaysia-Japan International Institute of Technology |
ID Code: | 40988 |
Deposited By: | Liza Porijo |
Deposited On: | 20 Aug 2014 08:19 |
Last Modified: | 15 Feb 2017 06:47 |
Repository Staff Only: item control page