Combined Heat and Power (CHP) scheme, also known as cogeneration is widely accepted as a highly efficient energy saving measure, particularly in medium to large scale chemical process plants. The advantages of a CHP scheme for a chemical plant are two fold: (i) to drastically reduce electricity bill from on-site power generation (ii) to save on fuel bills through recovery of the quality waste heat from power generation for process heating. In order to be effective, a CHP scheme must be placed at the right temperature level, in the context of an overall process system. Failure to do so might render a CHP venture worthless. This paper describes the procedure for an effective implementation of a CHP scheme using an ethyl benzene process as a case study. A key visualization tool in Pinch Analysis technique known as the grand composite curve is used to guide CHP integration, and allows it to be optimally placed within the overall process scenario. The study shows that appropriate CHP integration with the ethyl benzene process above the pinch can potentially result in significant savings on electricity cost of up to 87%.

Item Type:Article
Uncontrolled Keywords:Pinch analysis, composite curves, grand composite curves, cogeneration
Subjects:T Technology > TP Chemical technology
Divisions:Chemical and Natural Resources Engineering
ID Code:4010
Deposited By: Sharifah Rafidah Wan Alwi
Deposited On:16 Jul 2007 09:04
Last Modified:01 Nov 2017 04:17

Repository Staff Only: item control page