Universiti Teknologi Malaysia Institutional Repository

Experimenal investigation on the use of secondary refrigerant in freezer for energy savings

Haryono, Aries Prih and Sukamto, Edi and Sumeru, Sumeru and Ani, Farid Nasir (2013) Experimenal investigation on the use of secondary refrigerant in freezer for energy savings. In: 1st International Conference on Mechanical Engineering.

Full text not available from this repository.

Abstract

This study presents an experimental study on a freezer which has small cooling capacity. Typically a freezer uses primary refrigerant (direct cooling) to cool or freeze a product. In this study, a prototype of freezer using a compressor 250 W nominal power at 220V was designed and constructed. The freezer is operated on two conditions, that is, using primary and secondary refrigerant. R22 and R290 (propane) were used as primary refrigerant, whereas aqueous solution of propylene glycol as secondary refrigerant. Comparison of the system performance between the primary and the secondary refrigerant werepresented. Also, the experimental results showed that the use of R290 as primary refrigerant to replace R22 in the freezer could save electrical power consumption by 18.5%. Meanwhile, the use of the secondary refrigerant yielded energy savings by 33.19% compared with the primary refrigerant.

Item Type:Conference or Workshop Item (Paper)
Subjects:T Technology > TJ Mechanical engineering and machinery
Divisions:Mechanical Engineering
ID Code:37689
Deposited By: Liza Porijo
Deposited On:14 Apr 2014 04:32
Last Modified:28 Sep 2017 01:43

Repository Staff Only: item control page