Ibrahim, Sallehuddin and Md. Yunus, Mohd. Amri and Green, R. G. and Dutton, K. (2012) Concentration measurements of bubbles in a water column using an optical tomography system. ISA Transactions, 51 (6). pp. 821-826. ISSN 0019-0578
Full text not available from this repository.
Official URL: http://dx.doi.org/10.1016/j.isatra.2012.04.010
Abstract
Optical tomography provides a means for the determination of the spatial distribution of materials with different optical density in a volume by non-intrusive means. This paper presents results of concentration measurements of gas bubbles in a water column using an optical tomography system. A hydraulic flow rig is used to generate vertical air–water two-phase flows with controllable bubble flow rate. Two approaches are investigated. The first aims to obtain an average gas concentration at the measurement section, the second aims to obtain a gas distribution profile by using tomographic imaging. A hybrid back-projection algorithm is used to calculate concentration profiles from measured sensor values to provide a tomographic image of the measurement cross-section. The algorithm combines the characteristic of an optical sensor as a hard field sensor and the linear back projection algorithm.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Optical tomography, Tomography |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Electrical Engineering |
ID Code: | 33016 |
Deposited By: | Fazli Masari |
Deposited On: | 31 Jul 2013 08:31 |
Last Modified: | 30 Nov 2018 06:35 |