Idroas, M. and Abdul Rahim, R. and Fazalul Rahiman, M. H. (2010) Optical tomography system: charge-coupled device linear image sensors. Sensors & Transducers, 120 (9). pp. 62-69. ISSN 1726-5479
Full text not available from this repository.
Official URL: http://dx.doi.org/10.11113/jt.v78.9434
Abstract
This paper discussed an optical tomography system based on charge-coupled device (CCD) linear image sensors. The developed system consists of a lighting system, a measurement section and a data acquisition system. Four CCD linear image sensors are configured around a flow pipe with an octagonal-shaped measurement section, for a four projections system. The four CCD linear image sensors consisting of 2048 pixels with a pixel size of 14 micron by 14 micron are used to produce a high-resolution system. A simple optical model is mapped into the system's sensitivity matrix to relate the optical attenuation due to variations of optical density within the measurement section. A reconstructed tomographic image is produced based on the model using MATLAB software. The designed instrumentation system is calibrated and tested through different particle size measurements from different projections.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | image reconstruction, lasers, optical tomography system |
Subjects: | Q Science > QD Chemistry |
Divisions: | Chemical and Natural Resources Engineering |
ID Code: | 25961 |
Deposited By: | Narimah Nawil |
Deposited On: | 21 Jun 2012 08:27 |
Last Modified: | 22 Mar 2018 10:54 |
Repository Staff Only: item control page