Universiti Teknologi Malaysia Institutional Repository

Non-invasive ultrasonic tomography: liquid/gas flow visualization

Abdul Rahim, Ruzairi and Fazalul Rahiman, M. H. and Mohd. Taib, M. N. (2005) Non-invasive ultrasonic tomography: liquid/gas flow visualization. In: Proceeding of 1st Conference on Computers, Communication, and Signal Processing, 14-16 November 2005, Kuala Lumpur.

[img] PDF
947kB

Official URL: https://dx.doi.org/10.1109/CCSP.2005.4977199

Abstract

This paper presents the non-invasive ultrasonic tomography system for imaging liquid and gas flow. Transmission-mode approach has been used for sensing the liquid/gas two-phase flow, which is a kind of strongly inhomogeneous medium. The algorithms used to reconstruct the concentration profile for two-phase flow using fan-shaped beam scanning geometry were presented. Experiments showed that the performance of the system is acceptable. Results of the experiments using LBPA, HRA and HBRA were discussed.

Item Type:Conference or Workshop Item (Paper)
Uncontrolled Keywords:flow imaging, image reconstruction, Non-invasive, ultrasonic
Subjects:T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions:Electrical Engineering
ID Code:1793
Deposited By: Dr Zaharuddin Mohamed
Deposited On:15 Mar 2007 02:37
Last Modified:28 Aug 2017 01:38

Repository Staff Only: item control page