Abdul Rahim, Ruzairi and Fazalul Rahiman, M. H. and Mohd. Taib, M. N. (2005) Non-invasive ultrasonic tomography: liquid/gas flow visualization. In: Proceeding of 1st Conference on Computers, Communication, and Signal Processing, 14-16 November 2005, Kuala Lumpur.
PDF
947kB |
Official URL: https://dx.doi.org/10.1109/CCSP.2005.4977199
Abstract
This paper presents the non-invasive ultrasonic tomography system for imaging liquid and gas flow. Transmission-mode approach has been used for sensing the liquid/gas two-phase flow, which is a kind of strongly inhomogeneous medium. The algorithms used to reconstruct the concentration profile for two-phase flow using fan-shaped beam scanning geometry were presented. Experiments showed that the performance of the system is acceptable. Results of the experiments using LBPA, HRA and HBRA were discussed.
Item Type: | Conference or Workshop Item (Paper) |
---|---|
Uncontrolled Keywords: | flow imaging, image reconstruction, Non-invasive, ultrasonic |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Electrical Engineering |
ID Code: | 1793 |
Deposited By: | Dr Zaharuddin Mohamed |
Deposited On: | 15 Mar 2007 02:37 |
Last Modified: | 28 Aug 2017 01:38 |