Mahat, M. Mazwan and Osman, Kahar and Abdul Kadir, Mohammed Rafiq and Taib, Ishkrizat (2009) Study on the effect of stenting to aneurysms deformation. In: South East Asian Technical Universities Consortium(SEATUC) - 3rd SEATUC Symposium Proceeding, 25th - 26th February 2009, Johor Bahru, Malaysia.
|
PDF
- Published Version
2MB |
Abstract
Aneurysm has a tendency to enlarge over the years, depending on several factors. One of the treatments for aneurysm is by inserting stent in the blood vessel to reduce the pressure in the area. In this study, growth of the aneurysm is investigated using numerical approach. Both cases were considered, with and without the insertion of stent. The growth of the non stented aneurysm was compared with the actual measurement and good agreement was obtained. The same method was used to predict the growth of stented aneurysm. The result show promising reduction in the possibility to rupture for the aneurysm.
Item Type: | Conference or Workshop Item (Paper) |
---|---|
Additional Information: | ISSN : 1882-5796; Hybrid Twinning Program 2008 |
Uncontrolled Keywords: | aneurysm, stents, numerical, blood flow |
Subjects: | T Technology > TJ Mechanical engineering and machinery |