Universiti Teknologi Malaysia Institutional Repository

Probing and relating the morphology, structure and performance evolution of low pressure RO membranes under chlorine exposure

You, Meng and Feng, Guangli and Fei, Pengfei and Zhang, Yufeng and Cao, Zhen and Xia, Jianzhong and Lau, Woei Jye and Meng, Jianqiang (2021) Probing and relating the morphology, structure and performance evolution of low pressure RO membranes under chlorine exposure. Journal of Environmental Chemical Engineering, 9 (5). ISSN 2213-3437

Full text not available from this repository.

Official URL: http://dx.doi.org/10.1016/j.jece.2021.106223

Abstract

The polyamide layer of reverse osmosis (RO) membrane is susceptible to chlorination degradation. Guidelines for validation and integrity monitoring of the low pressure RO (LERO) membrane morphology and performance upon chlorination is still rarely reported. In this study, we selected three commercial LERO membranes (i.e., LP, ULP and LCLE) to study their structure and separation performance change for exposing to chlorine under both pressurized and static chlorination conditions, with different active chlorine concentrations and pH. At the pressurized testing, the membrane water flux increased at the initial stage due to the decrease of water passage restriction by the destroy of the hydrogen bond in the polyamide, and then the water flux sharply decreased and gradually leveled off, which should be resulted from the destroy of chemical structure of polyamide and membrane compaction under high pressure. The salt rejection slightly changed, presumably due to the combination of tightening effect, compactness and defect plugging by foulants. As for the static chlorination test, active chlorine concentration and chlorination time were not unequivocalness at the same chlorination intensity. Higher active chlorine concentration could cause more serious chlorination degradation. Based on the water flux change at neutral pH and under static chlorination conditions, a flux reduction equation with active chlorine concentration was fitted by y = axb (1<x<1000), which could help us to predict the water flux under a specific chlorine concentration and time.

Item Type:Article
Uncontrolled Keywords:polyamide, reverse osmosis membrane, thin film composite membrane
Subjects:Q Science > Q Science (General)
T Technology > TP Chemical technology
Divisions:Chemical Engineering
ID Code:94309
Deposited By: Yanti Mohd Shah
Deposited On:31 Mar 2022 15:29
Last Modified:31 Mar 2022 15:29

Repository Staff Only: item control page