Spiral groove bearing geometry variation effect on left ventricular assist device impeller performance

Empaling, S. and Md. Khudzari, A. Z. and Kadir, M. R. A. and Osman, K. and Hudzari, A. H. M. and Padzillah, M. H. and Talib, I. A. (2019) Spiral groove bearing geometry variation effect on left ventricular assist device impeller performance. CFD Letters, 11 (1). pp. 86-101. ISSN 2180-1363

Full text not available from this repository.

Official URL: http://www.akademiabaru.com/doc/CFDLV11_N1_P86_101...

Abstract

Mechanical heart assist device has been accepted as a reliable treatment modality for advanced heart failure patient option other than orthotropic heart transplantation. One type of the device is a centrifugal rotary mechanical blood pump that has an impeller levitated using a magnetic motor system in which, it reduces blood damage compared to its predecessors. Spiral Groove Bearing (SGB) is proposed as another design consideration to further decrease blood damage, increasing blood flow in the tight gaps, while maintaining pump performances. There were few studies investigating several aspects of SGB effect on blood flow within the mechanical blood pump, however no study has been done on the SGB geometry configurations, and its effect on device performance. In this study, two design factors of SGB geometry were simulated using computational fluid dynamics (CFD) software – a gap between impeller and housing, and SGB groove depths. The resulting variants were then evaluated using several performance indexes which are pump pressure output, average washout flow, hemolysis index, bearing load carrying capacity and pump efficiency. From the results, there are two conclusions that can be drawn. By deepening SGB groove depth, blood pump performance increased, while increasing the gap between the impeller and pump housing, most performance indexes were reduced. Scoring and screening method was also utilized to evaluate the best variant and it was found that, the variant with SGB groove depths 1000 μm and gap of 80 μm was the best in term of overall performances.

Item Type:Article
Uncontrolled Keywords:haemolysis, impeller design, mechanical heart assist device
Subjects:T Technology > TJ Mechanical engineering and machinery
Divisions:Mechanical Engineering
ID Code:91329
Deposited By: Narimah Nawil
Deposited On:30 Jun 2021 12:07
Last Modified:30 Jun 2021 12:07

Repository Staff Only: item control page