Universiti Teknologi Malaysia Institutional Repository

In vitro degradation behavior, antibacterial activity and cytotoxicity of TiO2-MAO/ZnHA composite coating on Mg alloy for orthopedic implants

Bakhsheshi-Rad, H. R. and Hamzah, E. and Ismail, A. F. and Aziz, M. and Daroonparvar, M. and Saebnoori, E. and Chamia, A. (2018) In vitro degradation behavior, antibacterial activity and cytotoxicity of TiO2-MAO/ZnHA composite coating on Mg alloy for orthopedic implants. Surface and Coatings Technology, 334 . pp. 450-460. ISSN 0257-8972

Full text not available from this repository.

Official URL: http://dx.doi.org/10.1016/j.surfcoat.2017.11.027

Abstract

Magnesium alloys as biodegradable materials have received great attention for orthopedic application as a result of their good biocompatibility, bioactivity, and mechanical properties. However, the clinical use of Mg alloys is restricted by high degradation rate. In order to reduce the degradation rate, TiO2 incorporated micro-arc oxidation (TM) coatings were prepared on Mg- Ca alloy using micro-arc oxidation (MAO). Subsequently, zinc-doped hydroxyapatite (ZH) coating was deposited by electrophoretic deposition (EPD) on the MAO coating. The electrochemical test results demonstrated that the deposition of ZH composite coatings on Mg alloy significantly reduces its corrosion rate and improves its charge transfer resistance. Antibacterial activity of the coating against Escherichia coli (E. coli) was studied using disk-diffusion and spread plate methods. The results revealed that the inhibition zone amplified after deposition of TM and ZH coatings on Mg alloy, whereas more inhibition zone was found around ZH coating. In addition, the number of E. coli colonies reduces to 92% after ZH coating implying its good antibacterial properties. The cytotoxicity test indicated that cell viability of MG63 osteoblast cells cultured with ZH extracts was higher compared to the TM coating and bare Mg alloy. These results confirm that Mg alloy coated by TM/ZH exhibits high corrosion resistance, antibacterial activity and favorable bioactivity and cytocompatibility, indicating their substantial potentials for biomedical applications.

Item Type:Article
Uncontrolled Keywords:Antibacterial activity, Cytotoxicity
Subjects:T Technology > TJ Mechanical engineering and machinery
Divisions:Mechanical Engineering
ID Code:86709
Deposited By: Widya Wahid
Deposited On:30 Sep 2020 09:04
Last Modified:30 Sep 2020 09:04

Repository Staff Only: item control page