Universiti Teknologi Malaysia Institutional Repository

Acoustic metamaterial for image detection

Abdul Hamid, Siti Zaleha and Abdul Rahim, Ruzairi and Abdul Rahim, Herlina and Daud, Nur Farah Hanis (2018) Acoustic metamaterial for image detection. Journal of Tomography System & Sensor Application (TSSA), 1 (2). pp. 1-13. ISSN 2636-9133

Full text not available from this repository.

Official URL: http://eprints.uthm.edu.my

Abstract

Image detection is important especially in medical for non destructive examination. Early development of image detection used high frequency for clearer image and caused heat development. Hence, there is a need to design metamaterial that can detect the image with lower frequency. This study focused on holey structured of three dimensions (3D) metamaterial. Methodology for this study can be divided into three parts which are metamaterial design, metamaterial testing, and performance analysis. The hole size, type of material and thickness of metamaterial designed will be varied for performance comparison. The image produce at the output plane of the metamaterial is clearly with the smallest scale size of hole which is 1.5 mm and the thickness of the metamaterial at 130 mm is equal with the operating wavelength. The device perfectly operated at lower frequency of 2.6 kHz.

Item Type:Article
Uncontrolled Keywords:image detection, acoustic metamaterial
Subjects:T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions:Electrical Engineering
ID Code:82259
Deposited By: Siti Nor Hashidah Zakaria
Deposited On:30 Sep 2019 09:00
Last Modified:19 Nov 2019 06:29

Repository Staff Only: item control page