Universiti Teknologi Malaysia Institutional Repository

Fabrication and characterization of chitosan nanoparticles and collagen-loaded polyurethane nanocomposite membrane coated with heparin for atrial septal defect (ASD) closure

Kaiser, E. and Jaganathan, S. K. and Supriyanto, E. and Ayyar, M. (2017) Fabrication and characterization of chitosan nanoparticles and collagen-loaded polyurethane nanocomposite membrane coated with heparin for atrial septal defect (ASD) closure. 3 Biotech, 7 (3). ISSN 2190-572X

[img]
Preview
PDF
1MB

Official URL: https://www.scopus.com/inward/record.uri?eid=2-s2....

Abstract

Atrial septal defect (ASD) constitutes 30–40% of all congenital heart diseases in adults. The most common complications in the treatment of ASD are embolization of the device and thrombosis formation. In this research, an occluding patch was developed for ASD treatment using a well-known textile technology called electrospinning. For the first time, a cardiovascular occluding patch was fabricated using medical grade polyurethane (PU) loaded with bioactive agents namely chitosan nanoparticles (Cn) and collagen (Co) which is then coated with heparin (Hp). Fourier transform infrared spectrum showed characteristic vibrations of several active constituents and changes in the absorbance due to the inclusion of active ingredients in the patch. The contact angle analysis demonstrated no significant decrease in contact angle compared to the control and the composite patches. The structure of the electrospun nanocomposite (PUCnCoHp) was examined through scanning electron microscopy. A decrease in nanofiber diameter between control PU and PUCnCoHp nanocomposite was observed. Water uptake was found to be decreased for the PUCnCoHp nanocomposite against the control. The hemocompatibility properties of the PUCnCoHp ASD occluding patch was inferred through in vitro hemocompatibility tests like activated partial thromboplastin time (APTT), prothrombin time (PT) and hemolysis assay. It was found that the PT and APTT time was significantly prolonged for the fabricated PUCnCoHp ASD occluding patch compared to the control. Likewise, the hemolysis percentage was also decreased for the PUCnCoHp ASD patch against the control. In conclusion, the developed PUCnCoHp patch demonstrates potential properties to be used for ASD occlusion.

Item Type:Article
Uncontrolled Keywords:Atrial septal defect, Blood compatibility, Cardiac patch, Electrospinning, Nanofibers, Textile technology
Subjects:T Technology > TP Chemical technology
Divisions:Biosciences and Medical Engineering
ID Code:75132
Deposited By: Fazli Masari
Deposited On:27 Mar 2018 05:53
Last Modified:27 Mar 2018 05:53