Ayob, S.M and Salam, Zainal and Azli, N.A (2007) Analysis of double loops discrete single input PI fuzzy for single phase inverter. In: Proceedings of the International Conference on Power Electronics and Drive Systems , 27th -30th Nov. 2007.

[img] PDF
Restricted to Repository staff only

1846Kb

Official URL: http://dx.doi.org/10.1109/PEDS.2007.4487854

Abstract

This paper presents an analysis of double loop PI-Fuzzy controller for a single phase inverter. The scheme comprises two feedback control loops arranged in a cascaded manner. The current in the filter inductor and voltage across the filter capacitor are sensed and fed back to the system to form the inner loop and the outer loop, respectively. Both loops are controlled by a discrete single input Pi-Fuzzy controller. It is derived using the "signdistance" method, which simplifies fuzzy set into a single input single output system. The work analyses the effect of fuzzy control surface for both loops in improving largesignal performance of the controller. Based on the analysis, the replacement of single input PI Fuzzy for voltage loop with a simple discrete linear PI controller will be justified.

Item Type:Conference or Workshop Item (Paper)
Uncontrolled Keywords:Double loops controller, PI fuzzy, UPS inverter