Modelling of a 3-phase induction motor under open-phase fault using matlab/simulink

Jannati, M. and Sutikno, T. (2016) Modelling of a 3-phase induction motor under open-phase fault using matlab/simulink. International Journal of Power Electronics and Drive Systems, 7 (4). pp. 1146-1152. ISSN 2088-8694

[img]
Preview
PDF
428kB

Official URL: https://www.scopus.com/inward/record.uri?eid=2-s2....

Abstract

The d-q model of Induction Motors (IMs) has been effectively used as an efficient method to analyze the performance of the induction machines. This study presents a step by step Matlab/Simulink implementation of a star-connected 3-phase IM under open-phase fault (faulty 3-phase IM) using d-q model. The presented technique in this paper can be simply implemented in one block and can be made available for control purposes. The simulated results provide to show the behavior of the star-connected 3-phase IM under open-phase fault condition.

Item Type:Article
Uncontrolled Keywords:Open-phase fault, Star-connected 3-phase IM
Subjects:T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions:Electrical Engineering
ID Code:71859
Deposited By: Fazli Masari
Deposited On:22 Nov 2017 12:07
Last Modified:22 Nov 2017 12:07

Repository Staff Only: item control page