F. A., Ani and E. M., Badawi and K. S., Kanan (2005) The effect of absorber packing height on the performance of a hybrid liquid desiccant system. Renewable Energy, 30 . pp. 2247-2256.
Full text not available from this repository.
Official URL: http://www.sciencedirect.com
Abstract
A hybrid system consisting of vapour compression unit, a liquid desiccant system, and a flat solar hot water collector were designed, fabricated and tested. This combination allowed for a separate control of humidity and temperature without energy penalty. Various packing heights of the absorber component were tested to determine the optimal performance of the combined unit. A 1000 mm packing height with cross-sectional area of 600×600 mm, proved to be the best height that gives promising improvements in the coefficient of performance of the vapour compression unit.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | Liquid desiccant; Packing material height; Absorber |
| Subjects: | T Technology > TJ Mechanical engineering and machinery |
| Divisions: | Mechanical Engineering |
| ID Code: | 7043 |
| Deposited By: | Mohamad Ali Duki |
| Deposited On: | 17 Dec 2008 03:35 |
| Last Modified: | 02 Sep 2010 09:18 |