Universiti Teknologi Malaysia Institutional Repository

Stability of talus component in total ankle arthroplasty

Abdul Kadir, Mohammed Rafiq and Kamsah, N. and Sabudin, H. (2008) Stability of talus component in total ankle arthroplasty. In: IFMBE Proceedings. Springer Berlin Heidelberg, pp. 453-456. ISBN 1680-0737

Full text not available from this repository.

Official URL: https://link.springer.com/chapter/10.1007/978-3-54...

Abstract

Early design of total ankle arthroplasty showed poor clinical outcomes and has since been regarded as an inferior procedure to arthrodesis. Initial attempt of ankle replacement used the design concept for total hip arthroplasty, with the stem implanted into the tibia and the cup implanted into the talus. The procedure was abandoned due to unsatisfactory early outcomes. However, the procedure is gaining popularity lately due to various clinical complications associated with bone fusion. New implants for TAR were introduced with designs that are more closely resembled the natural anatomy of the ankle. Biomechanical analysis of the replaced joint is crucial to achieve better understanding of its behaviour under physiological loading. At present, biomechanics research of the ankle joint after arthroplasty is fairly limited. In this study, finite element analysis was used to examine the stability of two design features of the talus component for total ankle replacement — the single-fin and the double-fin. Three dimensional model of the talus bone was reconstructed from CT dataset and the implant was positioned on the trochlea. The bone was assigned with cortical bone properties and pressure was applied on the superior surface of the implant. Nonlinear contact analysis was performed together with an in-house experimentally validated micromotion algorithm to predict the stability of the implants. Results showed that the talus component with double-fin was more stable than the one designed with single-fin. However, the magnitude of micromotion for both designs did not exceed the threshold limit for osseointegration, suggesting the adequacy of single-fin to provide primary stability.

Item Type:Book Section
Additional Information:Part 3 - Stability of Talus Component in Total Ankle Arthroplasty, pp. 453-456, (Mohammed Rafiq Abdul Kadir , N. Kamsah and H. Sabudin, Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Malaysia)
Uncontrolled Keywords:ankle arthroplasty, micromotion, talus component
Subjects:T Technology > TJ Mechanical engineering and machinery
Divisions:Mechanical Engineering
ID Code:6951
Deposited By: Mohamad Ali Duki
Deposited On:15 Dec 2008 07:35
Last Modified:25 Jul 2017 03:28

Repository Staff Only: item control page