Universiti Teknologi Malaysia Institutional Repository

Peak-to-peak tracking method for measurement of optical path difference: Revisited

Ley, H. H. and Yahaya, A. and Munajat, Y. (2015) Peak-to-peak tracking method for measurement of optical path difference: Revisited. Optik, 126 (24). pp. 5420-5422. ISSN 3040-26

Full text not available from this repository.

Official URL: http://www.dx.doi.org/10.1016/j.ijleo.2015.09.070

Abstract

This paper reports on the measurement of optical path difference of spectral interference signal by using the peak-to-peak tracking method in the wavelength domain. Numerical simulations are performed to produce the interference spectrum based on an all fibre Mach-Zehnder interferometer with a white light source. The peak-to-peak tracking method is improvised by measuring the wavelength value corresponding to bright fringes from the phase plot for determination of the optical path difference. The results are compared to the conventional peak-to-peak tracking method and measurement of the slope of phase against wavenumber plot. Optical path difference determined from the improvised method yields higher accuracy with lower uncertainty.

Item Type:Article
Uncontrolled Keywords:fibre interferometer, optical path difference, peak-to-peak tracking method
Subjects:Q Science > QC Physics
Divisions:Science
ID Code:58768
Deposited By: Haliza Zainal
Deposited On:04 Dec 2016 04:07
Last Modified:30 Aug 2021 16:29

Repository Staff Only: item control page