Amjad, Muhammad and Salam, Zainal and Facta, Mochammad and Ishaque, Kashif (2012) A simple and effective method to estimate the model parameters of dielectric barrier discharge ozone chamber. IEEE Transactions on Instrumentation and Measurement, 61 (6). pp. 1676-1683. ISSN 0018-9456
Full text not available from this repository.
Official URL: http://dx.doi.org/10.1109/TIM.2012.2188351
Abstract
This paper presents a simple yet effective method to determine the electrical model parameters of the dielectric barrier discharge (DBD) ozone chamber at frequencies above 20 kHz. The method is an alternative to the conventional Lissajous plot estimation method which appears to yield unsatisfactory results in this frequency range. Furthermore, the proposed technique allows for the chamber parameters to be determined at different frequencies-a flexibility which is not easily achievable using the typical Lissajous method. The measurement setup consists of a full-bridge inverter and a high-frequency variable inductor connected to the DBD chamber. The inductor can be adjusted to allow for parameter determination at different frequencies. The chamber parameters obtained from experimental results are validated by applying them in a high-voltage power supply for ozone generator.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Dielectric barrier |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Electrical Engineering |
ID Code: | 46532 |
Deposited By: | Haliza Zainal |
Deposited On: | 22 Jun 2015 05:56 |
Last Modified: | 12 Sep 2017 07:50 |
Repository Staff Only: item control page