Mohd. Yusoff, Mohd. Rashid (1987) Determination of total suspended particulate with and without the use of control filters. Journal of Environmental Science & Technology for Balanced Development . pp. 1-4. (Submitted)
|
PDF
- Submitted Version
174Kb |
Abstract
The use of preconditioned control filters as relative humidity correction method for total suspended particulate (TSP) mass collected on a glass-fiber hi-vol filter was investigated. The results showed that there was a difference in particulate concentrations calculated in each TSP filters with or without using the control filters, but the difference was insignificant (α=0.01). The difference was mainly due to the hygroscopic nature of the TSP samples rather than the filters. The study suggests that the effect of relative humidity (r.h) on glass-fiber filter can be neglected as long as the filters are equilibrated at least than or equal to 50% r.h before and after the sampling events.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | preconditioned control filters, total suspended particulate (TSP) |
| Subjects: | T Technology > TP Chemical technology |
| Divisions: | Chemical and Natural Resources Engineering (Formerly known) |
| ID Code: | 3744 |
| Deposited By: | Miss Sharifah Rafidah Wan Alwi |
| Deposited On: | 21 Jun 2007 08:46 |
| Last Modified: | 28 Oct 2010 04:21 |
Repository Staff Only: item control page