Universiti Teknologi Malaysia Institutional Repository

Calibration of high resolution digital camera based on different photogrammetric methods

Abdul Hamid, Nurul Farhah and Ahmad, Anuar (2013) Calibration of high resolution digital camera based on different photogrammetric methods. In: 8th International Symposium on digital Earth .

Full text not available from this repository.

Abstract

This paper presents method of calibrating high-resolution digital camera based on different configuration which comprised of stereo and convergent. Both methods are performed in the laboratory and in the field calibration. Laboratory calibration is based on a 3D test field where a calibration plate of dimension 0.4 m × 0.4 m with grid of targets at different height is used. For field calibration, it uses the same concept of 3D test field which comprised of 81 target points located on a flat ground and the dimension is 9 m × 9 m. In this study, a non-metric high resolution digital camera called Canon Power Shot SX230 HS was calibrated in the laboratory and in the field using different configuration for data acquisition. The aim of the calibration is to investigate the behavior of the internal digital camera whether all the digital camera parameters such as focal length, principal point and other parameters remain the same or vice-versa. In the laboratory, a scale bar is placed in the test field for scaling the image and approximate coordinates were used for calibration process. Similar method is utilized in the field calibration. For both test fields, the digital images were acquired within short period using stereo and convergent configuration. For field calibration, aerial digital images were acquired using unmanned aerial vehicle (UAV) system. All the images were processed using photogrammetric calibration software. Different calibration results were obtained for both laboratory and field calibrations. The accuracy of the results is evaluated based on standard deviation. In general, for photogrammetric applications and other applications the digital camera must be calibrated for obtaining accurate measurement or results. The best method of calibration depends on the type of applications. Finally, for most applications the digital camera is calibrated on site, hence, field calibration is the best method of calibration and could be employed for obtaining accurate measurement.

Item Type:Conference or Workshop Item (Paper)
Subjects:T Technology
Divisions:Geoinformation and Real Estate
ID Code:37320
Deposited By: Liza Porijo
Deposited On:03 Apr 2014 04:56
Last Modified:26 Sep 2017 08:04

Repository Staff Only: item control page