Universiti Teknologi Malaysia Institutional Repository

Experimental study of reinforced concrete columns concealing rain water pipe

Bakhteri, Jahangir and Syed Ariffin, Syed Ahmad Iskandar (2005) Experimental study of reinforced concrete columns concealing rain water pipe. Jurnal Teknologi B, 43 (B). pp. 13-26. ISSN 0127-9696

[img] PDF
192kB

Official URL: http://www.jurnalteknologi.utm.my/index.php/jurnal...

Abstract

An experimental study has been carried out to investigate the effect of concealing rain water pipes inside reinforced concrete columns in multistorey buildings. Fourteen columns in seven sets, having different sizes and reinforcement, with a PVC drain pipe positioned at the centre of crosssection of each one of them have been tested. An approximate method of columns’ alignment has also been developed and the alignment of the constructed columns has been carried out before their testing. The ultimate strength of the columns obtained from the present investigation have been compared with the design strengths recommended by the British code of practice (BS 8110) and the American code of practice (ACI). The columns showed significant reduction in their load carrying capacities and the safety factors obtained were much less than the nominal value usually recommended by various codes of practice.

Item Type:Article
Uncontrolled Keywords:Reinforced concrete column, load carrying capacity, drain pipe, stress, strain, factor of safety
Subjects:N Fine Arts > NA Architecture
Divisions:Built Environment
ID Code:3656
Deposited By: Norhayati Abu Ruddin
Deposited On:14 Jun 2007 08:21
Last Modified:01 Nov 2017 04:17

Repository Staff Only: item control page