Rahmat, Mohd. Fuaad and Tajdari, Teimour (2011) Particles mass flow rate and concentration measurement using electrostatic sensor. International Journal on Smart Sensing and Intelligent Systems, 4 (2). pp. 313-324. ISSN 1178-5608
|
PDF
847kB |
Official URL: http://s2is.org/Issues/v4/n2/
Abstract
In many industries where flow parameters measurement is essential to control manufacturing process, the use of a reliable, cost effective and high accuracy instrument is an important issue. Appropriate measurement method and design leads to improvement of pneumatic conveyors operation and process efficiency. This paper present an instrumentation design based on passive charge detection using a single electrostatic sensor. Two different sensor electrodes are applied to show the flexibility of electrostatic sensor application. A time domain signal processing algorithm is developed to measurement of mass flow rate and concentration profile from acquired electrical charge signal. The findings is led to a low cost and high accuracy design, the experimental test results of the design shows less than ±5% error between measured parameters and reference reading acquired from the manual weighing.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | pneumatic conveyors, passive charge, electrostatic sensor, mass indicator |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Electrical Engineering |
ID Code: | 29563 |
Deposited By: | Yanti Mohd Shah |
Deposited On: | 18 Mar 2013 08:16 |
Last Modified: | 25 Apr 2019 01:15 |