Dynamic supported liquid membrane tip extraction of glyphosate and aminomethylphosphonic acid followed by capillary electrophoresis with contactless conductivity detection

Hong, Heng See and Hauser, Peter C. and Sanagi, M. Marsin and Wan Ibrahim, Wan Aini (2010) Dynamic supported liquid membrane tip extraction of glyphosate and aminomethylphosphonic acid followed by capillary electrophoresis with contactless conductivity detection. Journal of Chromatography A, 1217 (37). 5832 - 5838. ISSN 0021-9673

Full text not available from this repository.

Official URL: https://doi.org/10.1016/j.chroma.2010.07.054

Abstract

A dynamic supported liquid membrane tip extraction (SLMTE) procedure for the effective extraction and preconcentration of glyphosate (GLYP) and its metabolite aminomethylphosphonic acid (AMPA) in water has been investigated. The SLMTE procedure was performed in a semi-automated dynamic mode and demonstrated a greater performance against a static extraction. Several important extraction parameters such as donor phase pH, cationic carrier concentration, type of membrane solvent, type of acceptor stripping phase, agitation and extraction time were comprehensively optimized. A solution of Aliquat-336, a cationic carrier, in dihexyl ether was selected as the supported liquid incorporated into the membrane phase. Quantification of GLYP and AMPA was carried out using capillary electrophoresis with contactless conductivity detection. An electrolyte solution consisting of 12 mM histidine (His), 8 mM 2-(N-morpholino)ethanesulfonic acid (MES), 75 µM cetyltrimethylammonium bromide (CTAB), 3% methanol, pH 6.3, was used as running buffer. Under the optimum extraction conditions, the method showed good linearity in the range of 0.01–200 µg/L (GLYP) and 0.1–400 µg/L (AMPA), acceptable reproducibility (RSD 5–7%, n = 5), low limits of detection of 0.005 µg/L for GLYP and 0.06 µg/L for AMPA, and satisfactory relative recoveries (90–94%). Due to the low cost, the SLMTE device was disposed after each run which additionally eliminated the possibility of carry-over between runs. The validated method was tested for the analysis of both analytes in spiked tap water and river water with good success.

Item Type:Article
Uncontrolled Keywords:supported liquid membrane, glyphosate, AMPA
Subjects:Q Science > QD Chemistry
Divisions:Science
ID Code:25114
Deposited By: Narimah Nawil
Deposited On:20 Sep 2017 09:26
Last Modified:09 Nov 2018 08:07

Repository Staff Only: item control page