Hamid, Muh. Imran and Anwari, Makbul and Taufik, Taufik (2008) Comparison of current control methods on carrier based VSI-PWM inverter drivers from line power quality aspects. TELKOMNIKA (Telekomunikasi Komputasi Elektronika Kendali), 6 (2). pp. 93-100. ISSN 1693-6930
|
PDF
180kB |
Abstract
This paper describes simulation result of two methods in current controlling for carrierbased VSI-PWM inverter: hysteresis and ramp comparison control. The simulation useful inselection of ASDs and generally–converter, from power quality point of view. Simulation resultshow that both ramp comparison and hysteresis control methods gives difference characteristicon line voltage and line current. A ramp comparison method is better in form of lower effect online current distortion compare with hysteresis control method. Meanwhile, for line voltagedistortion, hysteresis control seen better.
Item Type: | Article |
---|---|
Subjects: | T Technology > T Technology (General) T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Electrical Engineering |
ID Code: | 21957 |
Deposited By: | INVALID USER |
Deposited On: | 01 Feb 2012 07:44 |
Last Modified: | 13 Oct 2017 12:07 |
Repository Staff Only: item control page