A. Eltief, Salah and Ruslan, M. H. and Yatim, B. (2007) Drying chamber performance of V-groove forced convective solar dryer. Desalination, 2009 (1-3). pp. 151-155.
Full text not available from this repository.
Official URL: http://dx.doi.org/10.1016/j.desal.2007.04.024
Abstract
The performance of the drying chamber of a solar assisted drying system was analyzed. The solar assisted drying system consists of drying chamber, V-groove collector of 13.8 mð area, the auxiliary heater and two variable speed centrifugal fans. K-type thermocouples were used for temperature measurement, while solar radiation was measured by Eppley Pyranometer. Drying temperature is considered the most important factor in the drying operation. The accuracy of the temperature measurement is important in this analysis. The procedure for calculating the heat losses from drying chamber may be quite complex and often difficult to accurately determine the numerous variables. In this work standard equations under steady state condition were used to calculate the drying chamber efficiency and the heat losses from the chamber room.
Item Type: | Article |
---|---|
Additional Information: | The Ninth Arab International Conference on Solar Energy (AICSE-9), Kingdom of Bahrain |
Uncontrolled Keywords: | temperature, drying chamber, performance, heat transfer coefficient |
Subjects: | Q Science > Q Science (General) |
Divisions: | Science |
ID Code: | 17117 |
Deposited By: | Zalinda Shuratman |
Deposited On: | 30 Nov 2011 03:46 |
Last Modified: | 08 Feb 2017 01:14 |
Repository Staff Only: item control page