Universiti Teknologi Malaysia Institutional Repository

Investigation of the thermoluminescence dosimeter characteristics of multilayer ZnO(300 Nm)/Ag(50 Nm)/ZnO(X) thin films for photonic dosimetry applications

Thabit, Hammam Abdurabu and Ismail, Abd. Khamim and A. Kabir, Norlaili and Al Mutairi, Abdulmajeed Muidh and Bafaqeer, Abdullah and Alraddadi, Shoroog and Jaji, Nuru Deen and Sayyed, M. I. and Al-Ameri, Salem Mgammal (2023) Investigation of the thermoluminescence dosimeter characteristics of multilayer ZnO(300 Nm)/Ag(50 Nm)/ZnO(X) thin films for photonic dosimetry applications. Optical Materials, 137 (NA). NA. ISSN 0925-3467

Full text not available from this repository.

Official URL: http://dx.doi.org/10.1016/j.optmat.2023.113548

Abstract

This study demonstrated a novel sensor based on a semiconductor–metal–semiconductor multilayer film for photonic dosimetry that was synthesized at 300 °C using radiofrequency RF sputtering. The dosimetric properties of samples exposed to X-ray doses of up to 4 Gy were investigated. The system ZnO(300 nm)/Ag(50 nm)/ZnO(x nm) was chosen based hiest thermoluminescence TL intensity. The glow curve exhibited a single peak with a maximum temperature peak Tm of 246 °C. In addition, the proposed dosimeter has a linear dose-response up to 4 Gy. The heating rate with the highest TL intensity was 3 °C/s. The best annealing protocol for optimal TL intensity and minimum standard deviation was found at 200 °C and 30 min. Most dosimeter parameters were investigated, including homogeneity, precision, and fading properties. The kinetic parameters of the dosimeter were calculated and employed two methods: peak shape and initial rise. The results showed that the trap has activation energies at 0.51 and 0.53 eV and frequency factor between 0.25 × 108 and 0.5 × 109. Other features, like recycling, the receding of TL at room temperature, and optical fading, have been investigated. The suggested dosimeter demonstrated good radiation-measuring characteristics. The glow curve was immediately acquired, the annealing process was uncomplicated, and the dosimeter had a high sensitivity of 1.49 of TLD-100, making it suitable for radiation monitoring.

Item Type:Article
Uncontrolled Keywords:Ag–ZnO, dosimetry, photonic dosimetry, radiation, thermoluminescence, TLD
Subjects:Q Science > QC Physics
Divisions:Science
ID Code:106103
Deposited By: Yanti Mohd Shah
Deposited On:06 Jun 2024 08:30
Last Modified:06 Jun 2024 08:30

Repository Staff Only: item control page